Method Development and Validation of Polmacoxib in Capsule Dosage Form by RP-HPLC
Abstract
A simple and sensitive RP-HPLC method developed for estimation of Polmacoxib in bulk by using a high performance liquid chromatography with PDA detector using Phenomenex luna C18 column (250mmx4.6mm), 5 µm; mobile phase comprises of Water : ACN as (1:1) at the flow rate 1.0 ml/min and the wavelength of detection 238 nm and eluted at 8.12 minutes. The proposed method is validated for specificity, Linearity, Precision, accuracy, ruggedness, and Robustness. All the parameters were found within the acceptable limits. RP-HPLC method was a simple, reliable economic and acceptable and it confirmed that method is suitable for the intended use for routine quality control and assay of drugs. This method is successfully applied for the determination of commercial dosage form capsule preparation. This method is validated as per ICH (International conference on harmonization) Guidelines.
Keywords: Polmacoxib, RP-HPLC, ICH, PDA Detector, Precision
Keywords:
Polmacoxib, RP-HPLC, ICH, PDA Detector, PrecisionDOI
https://doi.org/10.22270/jddt.v11i4-S.4984References
Kim HT, Cha H, Hwang KY: Structural insight into the inhibition of carbonic anhydrase by the COX-2-selective inhibitor polmacoxib (CG100649). Biochem. Biophys. Res. Commun 2016; 1-6. https://doi.org/10.1016/j.bbrc.2016.07.114
Lee M, Yoo J, Kim JG, Kyung H S, Bin SI, Kang SB, Choi CH, Moon Y W, Kim YM, Han SB, In Y, Choi CH, Kim J, Lee BK, Cho S: A Randomized, Multicenter, Phase III Trial to Evaluate the Efficacy and Safety of Polmacoxib Compared with Celecoxib and Placebo for Patients with Osteoarthritis. Clin Orthop Surg 2017; 9:439-457. https://doi.org/10.4055/cios.2017.9.4.439
Song IG, Jung KU, Kim HO, Kim H, Chun HK: An unusual case of colon perforation with multiple transmural ulcers after use of polmacoxib and everolimus in a metastatic breast cancer patient: A case report Ann Coloproctol 2020; 1-20.
Kyeon SY, Bang HC, Sohn YT: Solid state of a new COX-2 inhibitor CG100649 Characterization, dissolution, and transformation. J Therm Anal Calorim 2017; 1-8. https://doi.org/10.1007/s10973-017-6101-2
Prathapa B, Deyb A, Raoa GHS, Johnsona P, Arthanariswaran P: A Review - Importance of RP-HPLC in Analytical Method Development. IJNTPS 2013; 1-9.
Kumar DS, Kumar H: Importance of RP-HPLC in analytical method development: A Review. Int. J. Pharm. Sci. Res 2012; 3(12):4626-4633.
Patel S S, Ladva B J , Nayak B S, Patel S J, Mahida V M: Development of stability-indicating hplc method for simultaneous estimation of nebivolol hydrochloride and valsartan in tablet dosage form. World J Pharm Pharm Sci 2015; 4(6):662-670.
Ritihaas C S, Prakash B B: RP-HPLC Method Development and Validation for Simultaneous Estimation of Olmesartan Medoxomil and Hydrochlorothiazide. Int J Pharm Bio Sci 2015; 6(1):180-187.
Das S C, Roy S, Arefeen S, Rouf S S: Development and Validation of RP-HPLC Method for Quantitative Estimation of Vinpocetine in Pure and Pharmaceutical Dosage Forms. Chromatogr. Res. Int 2011; 1-7. https://doi.org/10.4061/2011/801656
N Itagimatha, D H Manjunatha: RP-HPLC-UV method development and validation for simultaneous determination of terbutaline sulphate, ambroxol HCl and guaifenesin in pure and dosage forms. Ann Pharm F 2019 Jul; 77(4):295-301. https://doi.org/10.1016/j.pharma.2019.02.004
Subramanian V B, Katari N K, Dongala T, Jonnalagadda S B: Stability-indicating RP-HPLC method development and validation for determination of nine impurities in apixaban tablet dosage forms. Robustness study by quality by design approach'' ''Biomed Chromatogr. 2020 Jan; 34(1):e4719. https://doi.org/10.1002/bmc.4719
Singh O, Kumar R, Kulkarni O, Reddanna P, Polamarasettyparoy: Understanding the Dual Inhibition of COX-2 and Carbonic Anhydrase-II by Celecoxib and CG100649 Using Density Functional. Theory Calculations and other Molecular Modelling Approaches Protein & Peptide Letters. 2015; (10):903-912. https://doi.org/10.2174/0929866522666150622102131
Tripathi, K.D. Essentials of Medical Pharmacology, 6th ed. Jaypee Brothers Medical Publishers. 2008. P. 248-249. https://doi.org/10.5005/jp/books/10282
Indian Pharmacopoeia, The Indian Pharmacopoeia Commission, Ghaziabad.
ICH Q2B, Validation of Analytical Procedures: Methodology. 1997.
International Conference on Harmonization (ICH) Topic Q2A, Validation of Analytical Procedures, Methodology, CPMP/ICH/281, (1995).
Sethi, P D, High Performance Liquid Chromatography, 1st ed. CBS Publishers and Distributors. 2001. P. 3-16.
Snyder,L R, Glajch J L, Kirkland J J, Practical HPLC Method Development, 2nd ed. John Wiley & Sons, Inc, A Wiley-interscience Publication, USA, 1997. P. 2-9. https://doi.org/10.1002/9781118592014
Published
Abstract Display: 2758
PDF Downloads: 1405
PDF Downloads: 671 How to Cite
Issue
Section
Authors who publish with this journal agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0). that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).

.