Available online on 22.03.2023 at http://jddtonline.info
Journal of Drug Delivery and Therapeutics
Open Access to Pharmaceutical and Medical Research
Copyright © 2023 The Author(s): This is an open-access article distributed under the terms of the CC BY-NC 4.0 which permits unrestricted use, distribution, and reproduction in any medium for non-commercial use provided the original author and source are credited
Open Access Full Text Article Research Article
Development of Stability Indicating RP-HPLC Method for Tizanidine Hydrochloride in Bulk Drug and Pharmaceutical Dosage Form
Rekha Rani1*, Lokesh Chaudhari2, Devendra Dhanorya3, Damodar Ahirwar3, Shivam Kori3, Vinita Ahirwar4, Sashi Raj5, Saraswati Kurmi6
1 Anjali College of Pharmacy and Science, NH-2, Agra-Firozabad Road, Etmadpur, Agra, UP, 283202
2 Bhagwati College of Pharmacy, 77, Kotana Rd, Baraut, UP, 250611
3 Department of Pharmaceutical Sciences, Dr. Harisingh Gour Central University, Sagar, MP, 470003
4Bhagyoday Tirth Pharmacy College, Shastri Nagar, Khurai road, Sagar, MP, 470002
5 Shri Bhagwat Prasad Singh Memorial Institute of Higher Education, Deo More G. T. Road Aurangabad, Bihar 824203
6 Pahalwan Gurudeen College of Science and Technology, Panari, Lalitpur, UP, 284403
|
Article Info: _______________________________________________ Article History: Received 03 Jan 2023 Reviewed 16 Feb 2023 Accepted 04 March 2023 Published 22 March 2023 _______________________________________________ Cite this article as: Rani R, Chaudhari L, Dhanorya D, Ahirwar D, Kori S, Ahirwar V, Raj S, Kurmi S, Development of Stability Indicating RP-HPLC Method for Tizanidine Hydrochloride in Bulk Drug and Pharmaceutical Dosage Form, Journal of Drug Delivery and Therapeutics. 2023; 13(3):131-137 DOI: http://dx.doi.org/10.22270/jddt.v13i3.5780 _______________________________________________*Address for Correspondence: Rekha Rani, Anjali College of Pharmacy and Science, NH-2, Agra-Firozabad Road, Etmadpur, Agra, UP, 283202, India |
Abstract ___________________________________________________________________________________________________________________ The quantitative analysis of tizanidine hydrochloride in both pharmaceutical dosage form and bulk medication has been developed and validated using an easy, affordable, quick, and unique isocratic HPLC approach. Tizanidine hydrochloride was separated isocratically using Waters symmetry C18 ODS as the stationary phase (250×4.6 mm, 5μm particle size), a flow rate of 1.0 ml/min, and a UV detector to track the eluate at 230 nm. The drug and its degradation products could be separated using the mobile phase, which was made up of acetonitrile: phosphate buffer (20:80 v/v) and pH-adjusted to 3.0 by ortho-phosphoric acid. Linearity, accuracy (recovery), precision, specificity, and robustness of the approach were all validated. For the range of 4-80 μg/ml, the linearity of the technique was satisfactory (correlation coefficient 0.999). Between 100.4 to 101.3% of the tizanidine hydrochloride was recovered from the medicinal dosage form. In order to analyze the samples, tizanidine hydrochloride was put under stress conditions, including hydrolysis (acid, base), oxidation, photolysis, and heat degradation. The tizanidine hydrochloride forced degradation study demonstrated that it decomposed under minimal conditions. Under the other stress scenarios examined, the medication remained steady. It was discovered that tizanidine hydrochloride was significantly more stable in its solid state than in its solution condition. The breakdown products were clearly distinguishable from the primary peak. The validation method may be useful for routine analysis of tizanidine hydrochloride as bulk drug, in respective dosage forms, for dissolution studies, and as a stability indicating assay method in pharmaceutical laboratories and industries because the forced degradation study proves the method's stability indicating power. Keywords: RP-HPLC, Tizanidine hydrochloride, Forced degradation, Method validated |
INTRODUCTION
5-Chloro-N-(4,5-dihydro-1H-imidazol-2-yl)-2,1,3-benzothiadiazol-4-amine hydrochloride is tizanidine hydrochloride (TIZ, Figure 1). It is an alpha2 adrenergic agonist and a muscle relaxant1. It is used to treat medical conditions such multiple sclerosis, spastic diplegia, back pain, and several other ailments to the spine or central nervous system that result in muscular spasms2,3, cramping, and tightness. When dried, TIZ has a C9H8ClN5S.HCl content that is between 99.0% and 101.0%. It is a white to light yellow-white crystalline powder when it is present. It is essentially insoluble in acetic anhydride and acetic acid, but somewhat soluble in water and ethanol. The equivalent of 2 mg of the base administered as a single dosage is the typical first daily dose for the therapy of spasticity. TIZ is used in doses equating to 2 to 4 mg of the base three times per day in order to relieve painful muscle spasm. In terms of clinical practice, NSAIDs are the most often prescribed medications by doctors for inflammatory disorders4. An essential step in the process of developing a medicinal product is stability testing.
The goal of stability testing is to demonstrate how the quality of a drug ingredient or drug product changes over time under various environmental circumstances, including as temperature, humidity, and light. This information is used to determine storage conditions, retest intervals, and shelf lives5,6. The assay of the active ingredient and the degradation products produced during stability studies are the two key components of stability studies that are crucial for determining shelf lives. The International Conference on Harmonization (ICH) 7 recommends using a stability indicating method for the assay of a drug product in a stability test sample. The goal of this work was to create an analytical LC approach that was quick, accurate, and could be used to analyze a dose form of TIZ and determine its stability. The United States Pharmacopoeia (USP) suggests using the HPLC technique to identify tizanidine (I) in tablets and raw materials8. Other techniques for determining tizanidine hydrochloride have been published in the literature, including spectrophotometry9–16, voltammetry17–19, GC20–21, TLC22–24, and HPLC16, 22, 25–28. None of the available methodologies permits analysis of the tizanidine hydrochloride in pharmaceutical dosage forms in the presence of their breakdown products. This article presents the creation and validation of a speedy, affordable, precise, and accurate stability-indicating isocratic reversed phase HPLC technique for the measurement of tizanidine hydrochloride in the presence of its degradation products in compliance with ICH recommendations 12. This study primarily focuses on the forced degradation of tizanidine hydrochloride under stressful conditions like acidic and basic hydrolysis, oxidation, heat, and light, as well as the validation of a method for precisely quantifying tizanidine hydrochloride in bulk medication and solid dosage form.
Figure 1: Molecular structure of tizanidine hydrochloride
EXPERIMENTAL
Chemicals and reagents
Endoc pharma labs limited Rajkot (Gujarat, India) generously provided tizanidine hydrochloride bulk medicine (quality 98.9%), and Sirdalud 2/4mg tizanidine tablets were obtained from the neighborhood market. The following chemicals were purchased from Merck Fine Chemicals Mumbai, India: acetonitrile (HPLC grade), orthophosphoric acid, sodium hydroxide (NaOH), hydrochloric acid (HCl), and hydrogen peroxide (H2O2). Throughout the experiment, water of the double HPLC grade was used. The other compounds were analytical- or HPLC-grade substances. Working standard was dissolved in mobile phase and diluted with the same solvent to create standard stock solution (1 mg/ml) of TIZ. This stock solution was diluted with diluent to create standard calibration solutions (4-80μg/ml) for the evaluation of linearity. Chromatography
With a 2695 separation module, 2996 PDA detector, performance plus 4 channel in line degasser, auto injector, quaternary high pressure gradient pump, 100μl sample loop, 200μl syringe, and column heater, the Waters alliance HPLC system is geared for high-performance separation. Using Empower login software, all of the data from the Waters Alliance HPLC system was collected and processed. Using a mobile phase of acetonitrile: phosphate buffer (20:80 v/v) and ortho-phosphoric acid to adjust pH to 3.0, the chromatographic analysis was carried out. Before use, these were degassed by sonication and filtered through a 0.45-inch membrane filter. During analysis at room temperature, the mobile phase was pumped isocratically at a flow rate of 1.0 ml/min. The injection volume was 20μl, the run time was 10 min, and the eluent was detected at 230 nm on a C18 ODS with Waters symmetry (250 × 4.6 mm, 5µm particle size).
Analysis of dosage forms
Twenty tablets (2-4mg each) were weighed, and the mean weight of the tablets was calculated. Two milligrams of TIZ were diluted in 50 milliliters of diluent, sonicated for 30 minutes, and then filtered through whatman paper no. 41. The filtrate was properly diluted to achieve a concentration of 20, 40, and 60µg/ml before being tested.
Forced degradation study
To study the impact of acid, 10 mg of TIZ that had been precisely weighed was dissolved in 9 ml of mobile phase, and the volume was then made up to 10 ml with 1N HCl to get a concentration of 1000μg/ml (i.e., the concentration of HCl in solution was 0.1 N). This solution was then kept on a water bath at 80°C for 60 minutes. To make the 40μg/ml solution, aliquots of the aforesaid solution were neutralized with 1N NaOH and diluted with diluents. A chromatogram was created when the sample solution was examined. To explore the impact of the alkali, 10 mg of TIZ that had been precisely weighed was dissolved in 9 ml of mobile phase and then volume was increased to 10 ml with 1N sodium hydroxide to create a solution of 1000μg/ml (i.e. conc. of NaOH in solution was 0.1N). The aforementioned mixture was heated to 80°C in a water bath for 60 minutes. To make the 40μg/ml solution, aliquots of the aforesaid solution were neutralized with 1N HCl and diluted with diluents. The sample solution's chromatogram was recorded after analysis. To investigate the impact of oxidizing environments, precisely weighed 10 mg of TIZ were dissolved in 9 ml of mobile phase, and then volume was made up to 10 ml with 30.0% hydrogen peroxide to achieve a solution of 1000μg/ml (i.e., the concentration of hydrogen peroxide in the solution was 3%) and kept on a water bath at 80°C for 60 min. To create a 40μ g/ml solution, aliquots of the aforesaid solution were neutralized with 1N HCl and diluted with diluents. A chromatogram was recorded after the sample solution was examined. For three days, 1.0 gram of precisely weighed TIZ was maintained in an oven set at 80 °C to study the effects of temperature. Every 24 hours, a sample containing 10 mg of the medication was removed and diluted in accordance with protocol. A chromatogram was recorded after the preparation of aliquots of a 40μg/ml concentration. In order to investigate the impact of UV radiation, precisely weighted about 1.0 gram TIZ was exposed to short- and long-wavelength UV radiation (222 and 366 nm, respectively) for 48 hours. Samples containing 10 mg of the drug were taken out and diluted as directed after every 24 hours. A chromatogram was recorded after the preparation of aliquots of a 40μg/ml concentration.
Method validation
According to ICH criteria, the method was validated for linearity, specificity, limits of detection (LOD), limits of quantification (LOQ), system adaptability, accuracy, precision, robustness, and stability. Peak purity was obtained using a photodiode-array detector to evaluate specificity. Test solutions of TIZ were made at six concentrations ranging from 4-80μg/ml to verify linearity. The calibration graphs were created by graphing peak area against concentration after each solution was injected in triplicate. On three consecutive days, linearity was examined over the same concentration range. Also, the calibration plot's Y-intercept and slope's RSD (%) were calculated.
The limits of detection (LOD) and quantification (LOQ) for TIZ were determined, as the levels for which signal-to-noise ratios were 3:1 and 10:1, respectively, by injecting a series of dilute solutions of known concentration. Precision was achieved by measuring the drug concentration in the injection six times to estimate RSD (%). Two analysts evaluated intermediate (inter-day) precision on separate days in the same laboratory. By measuring recovery after adding known dosages of the medicine (80, 100, and 120% of the label claim of 1gm TIZ per injection) to the placebo, the accuracy of the procedure was investigated. At each recovery level, three samples were collected, and the results were computed using the calibration plot. By purposefully changing the experimental circumstances and analyzing the impact on the resolution of TIZ from the main product produced by deterioration under standard conditions, the robustness of the approach was evaluated. Instead of using acetonitrile: phosphate buffer (20:80 v/v) and adjusting the pH to 3.0 with ortho-phosphoric acid, acetonitrile: phosphate buffer (25:75 v/v) and adjusting the flow rate to 1.0 ml/min, 0.8 ml/min, and 1.2 ml/min were used as the mobile phase and flow rates, respectively. All other conditions were maintained constant during these testing at their ideal levels. Analysis after 24, 48, and 72 hours, comparison of the results with those from freshly prepared standard solutions, and calculation of RSD were used to test the stability of TIZ and sample solutions (at ambient temperature).
RESULTS AND DISCUSSION
Optimization of chromatographic conditions
To achieve resolution between TIZ and its degradation products was the main goal of creating this stability-indicating HPLC technique. Waters Alliance HPLC system with 2695 separation module, 2996 PDA detector, and C18 column was used for the planned work to achieve this. An attempt was made to quantify TIZ using acetonitrile: phosphate buffer (20:80 v/v) and ortho-phosphoric acid to adjust the pH to 3.0 as the mobile phase with acceptable system suitability parameters (RT, tailing factor, number of theoretical plates, and HETP) at 230 nm as the detection wavelength. With a correlation coefficient of r2 = 0.9998 and the equation AUC = 41.716Conc-2.250, linearity was shown to exist between 4-80μg/ml. 25°C was the column's temperature. Retention periods were around 5.417 ±0.5 min for the primary peak and less than 10 min for the degradation products, while the tailing factor for TIZ was < 2. (Figure 2). High productivity and low cost of analysis per sample were produced as a result of the reduced overall runs time.
Forced degradation study
While determining the stability-indicating characteristics of analytical procedures, Bakshi et al.30 recommended a target degradation of 20–80% because even intermediate degradation products shouldn't interfere with any stage of drug analysis. Even after prolonged exposure to acid, base, and oxidizing agents, the parameters employed for forced degradation could not be altered to achieve deterioration in this range under any other circumstances. Peak purity test findings indicated that the TIZ peak was homogeneous under all the stress conditions examined. The mass balance of TIZ in stress samples was nearly 100%, and furthermore, the method's capacity to indicate stability was confirmed by the assay of unaffected TIZ in the tablets. Table 1 provides a summary of the findings from studies on forced deterioration. Data on the chromatographic peak purity were taken from the spectrum analysis report; a peak with a peak purity of greater than 99 is considered to be homogeneous. The degradation experiments' peak purity for TIZ was in the range 99.9-100.0, suggesting homogenous peaks and proving the method's specificity. Figure 3 displays, respectively, chromatograms from the solutions obtained following deterioration under acidic, basic, oxidizing, and photolytic conditions. There were no peaks that co-eluted with the TIZ peak, indicating that the approach allowed for a more precise study of TIZ and the presence of its breakdown products.
Figure 2: Standard chromatogram of tizanidine hydrochloride
(A)
(B)
(C)
(D)
Figure 3: Typical chromatogram obtained after degradation of tizanidine hydrochloride under (A) acidic conditions, (B) basic conditions, (C) oxidizing conditions, (D) photolytic condition
Method validation
Peak purity for the drug substance and drug degradation products was >99.9% at 230 nm, demonstrating the purity of the analyte peaks and excluding the interference of formulation excipients and degradation products. For a 20μl injection volume, the LOD and LOQ for TIZ were 0.05 and 0.22μg/ml, respectively. Table 2 contains a list of the regression analysis findings together with information on system suitability. The RSD of TIZ peak area was less than 2% when precision was assessed using a six-fold examination of drug injection, demonstrating the method's dependability. Table 3 contains the outcomes of the precision evaluation. Table 4 lists the results of the recovery determination, whereas Table 5 displays the outcomes of the robustness test.
Table 1: Results from analysis of samples from the forced degradation study, showing percentage degradation andpeak purity of tizanidine hydrochloride
|
Stress condition and duration |
% degradation |
Peak purity* |
|
Acid degradation 0.1N HCl–80°C /60 min |
4.8 |
99.928 |
|
Base degradation 0.1N NaOH–80°C/60 min |
56.56 |
99.983 |
|
Oxidizing degradation (3% H2O2)-60 min |
9.3 |
99.912 |
|
Thermal degradation- 80°C /48 hrs |
0 |
99.971 |
|
UV light/222nm/48 h |
0 |
100.23 |
|
UV light/366nm/48 h |
0 |
101.34 |
*Peak purity values in the range of 99-100 indicate a homogeneous speak
Table 2: Results from regression analysis and system suitability data
|
Parameters |
Tizanidine hydrochloride |
|
Retention time* |
5.417± 0.5 min |
|
Tailing factor* |
1.10 |
|
Theoretical plate* |
13965 |
|
Linear range (μg/ml) |
4-80 |
|
Limits of detection (μg/ml) |
0.05 |
|
Limits of quantification (μg/ml) |
0.22 |
|
Linear equation |
41.716Conc-2.250 |
|
Slope |
41.716 |
|
Intercept |
-2.250 |
|
Correlation coefficient |
0.9998 |
*Mean of six readings
Table 3: Result of precision of test method of tizanidine hydrochloride
|
Std. conc. (μg/ml) |
Repeatability |
Intermediate precision |
|
|
Day to day |
Analyst to analyst |
||
|
4 |
100.2 |
99.80 |
99.26 |
|
20 |
102.7 |
103.9 |
100.19 |
|
40 |
99.60 |
102.3 |
99.80 |
|
60 |
101.00 |
100.5 |
99.02 |
|
80 |
100.19 |
100.9 |
100.12 |
|
Mean |
100.738 |
101.48 |
99.678 |
|
S.D. |
1.205 |
1.632 |
0.519 |
|
% R.S.D. |
1.196 |
1.608 |
0.520 |
*Mean of fifteen determinations (3 replicates at 5 concentration level)
Table 4: Recovery of tizanidine hydrochloride
|
Level of addition |
Std. drug sol. added (μg/ml) |
% mean* recovered |
|
50 |
20 |
100.4 |
|
100 |
40 |
101.0 |
|
150 |
60 |
101.3 |
Table 5: Results from robustness testing
|
Change in Parameters
|
Values |
Component |
RT (min) |
T. Plates
|
Tailing Factor |
% Assay |
SD |
% RSD |
|
Normal conditions |
As per specified method |
Tizanidine |
5.420 |
13974 |
1.11 |
98.3 |
1.1314 |
1.15 |
|
Flow Rate (±0.2ml) |
0.8 |
Tizanidine |
6.777 |
15657 |
1.13 |
98.1 |
||
|
1.2 |
Tizanidine |
4.523 |
12531 |
1.09 |
98.0 |
|||
|
Column Change |
Inertsil ODS 3V, 250 x 4.6 mm, 5µ |
Tizanidine |
5.686 |
15091 |
1.11 |
98.3 |
||
|
pH change (±0.2) |
2.8 |
Tizanidine |
5.531 |
14602 |
1.11 |
99.5 |
||
|
3.2 |
Tizanidine |
5.642 |
14681 |
1.11 |
99.0 |
|||
|
Composition of Mobile Phase (Buffer : ACN) |
78:22 |
Tizanidine |
4.761 |
13469 |
1.11 |
99.7 |
||
|
82:18 |
Tizanidine |
6.810 |
15220 |
1.11 |
99.6 |
|||
|
Column Temp. (500C±5) |
45°C |
Tizanidine |
5.835 |
14574 |
1.12 |
96.8 |
||
|
55°C |
Tizanidine |
5.463 |
14818 |
1.12 |
96.4 |
CONCLUSION
The technique created for the quantitative analysis of tizanidine hydrochloride is quick, exact, precise, and selective. Peak purity tests under all stress situations revealed that the drug peak was pure, proving that the process is stable. In other words, it can be said that the method created can be used to successfully quantify the drug even when its degradation product and excipients are present. All of the characteristics studied yielded satisfactory findings, and the methodology was fully validated. It is possible to evaluate the stability of tizanidine hydrochloride in the bulk medication using the stability-indicating method. In pharmaceutical laboratories and businesses, the approach is easily applied for routine analysis of tizanidine hydrochloride as a bulk drug, in the appropriate dosage forms, for dissolving investigations, and as a stability-indicating test method.
REFERENCES
1. Moffat AC. Clarks isolation and identification of drugs. 3rd ed. London: Pharmaceutical Press; 2005.
2. Parfitt K ed. Martindale, The Extra Pharmacopoeia, 36th ed. London: The Pharmaceutical Press; 2009. p. 984.
3. Merck Index. An Encyclopedia of Chemicals, Drug and Biological, 13th ed. Merck, NJ, USA, 2001.
4. Zaman M, Hanif M, Murtaza H. Development and validation of RP-HPLC method for simultaneous estimation of tizanidine HCl and meloxicam in bilayer mucoadhesive buccal films. Acta Pol Pharm-Drug Res. 2018; 75(4):851-9. https://doi.org/10.32383/appdr/80742
5. Pugh J. Kinetics and Product Stability, The Science of Dosage Form Design, Aulton ME, eds. Churchill Livingstone, London, 2002, p. 109.
6. Carstensen JT. Modus Operendi for Stability Programme, Drug Stability and Practices, Marcel Dekker, Inc., New York, 1995, p.487.
7. International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use, Stability testing of New Drug Substances and Products. QIA (R2), August, 2003.
8. The United States Pharmacopoeia 30, the National Formulary 25, US Pharmacopeial Convention: Rockville, MD. 2007, Electronic version.
9. Shankar MB, Shah DA, Geetha M, Mehta FA, Mehta RS, Bhatt KK. Simultaneous spectrophotometric determination of tizanidine and diclofenac in tablets. Ind J Pharm Sci 2004; 66:332-336.
10. Dahiya R, Chaudhary H, Rathee P, Nagori BP. Spectrophotometric method for the estimation of tizanidine in bulk and tablet dosage forms. Indian Pharmacist 2008; 7:59-62.
11. Dashora K, Gopal G, Saraf S, Swarnlata S. Spectrophotometric determination of aceclofenac and tizanidine hydrochloride. Asian J Chem 2007; 19:3289-3291.
12. Ashok K, Kumar R, Anroop B, Tuli k, Gupta AK. Spectrophotometric method for estimation of rofecoxib and tizanidine hydrochloride in tablets. Indian Pharmacist 2007; 6:61-64.
13. Prabhakar B, Manjunath K, Shobha R, Appala S. Development and validation of spectrophotometric methods for the estimation of tizanidine in pharmaceutical dosage forms. J Ind Council Chem 2005; 22:37-41.
14. Reddy T, Rama S, Rao SV, Murali M, Rao AN, Sastry CSP. Simple spectrophotometric methods for the determination of tizanidine. J Ind Council Chem 2003; 20:26-29.
15. Dashora K, Saraf S, Saraf S. Simultaneous spectrophotometric method for the determination of nimesulide and tizanidine hydrochloride. Oriental J Chem 2006; 22:167-168.
16. Sivasubramanian L, Devarajan. Spectrophotometric and HPLC methods for simultaneous estimation of tizanidine and valdecoxib from tablets. Int J ChemTech Res 2009; 1:96-102.
17. Kauffmann JM, Ruiz BL, Gotor MF, Patriarche GJ. Electrochemical behaviour of tizanidine at solid electrodes. J Pharm Biomed Anal 1992; 10:763-767. https://doi.org/10.1016/0731-7085(91)80077-M
18. Tuncel M, Dogrukol D. Study on the polarographic behaviour and determination of tizanidine. Anal Lett 1992; 25:1087-1094. https://doi.org/10.1080/00032719208020061
19. Bouklouze AA, El Jammal A, Vire JC, Patriarche GJ. Comparative study of three polymeric membrane electrodes selective to tizanidine. Anal Chim Acta 1992; 257:41-48. https://doi.org/10.1016/0003-2670(92)80148-Z
20. Gunnar T, Mykkanen S, Ariniemi K, Lillsunde P. Validated semiquantitative/ quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection. J Chromatogr B 2004; 806:205-219. https://doi.org/10.1016/j.jchromb.2004.04.005
21. Lee J, Seo JH, Kim DY. Determination of tizanidine in human plasma by gas chromatography- mass spectrometry. Analyst 2002; 127:917-920. https://doi.org/10.1039/b202271k
22. Kaul N, Dhaneshwar SR, Agrawal H, Kakad A, Patil B. Application of HPLC and HPTLC for the simultaneous determination of tizanidine and rofecoxib in pharmaceutical dosage form. J Pharm Biomed Anal 2005; 37:27-38. https://doi.org/10.1016/j.jpba.2004.09.036
23. Mahadik KR, Paradkar AR, Agrawal H, Kaul N. Stability indicating HPTLC determination of tizanidine hydrochloride in bulk drug and pharmaceutical formulations. J Pharm Biomed Anal 2003; 33:545-552. https://doi.org/10.1016/S0731-7085(03)00304-2
24. Pawar UD, Sulebhavikar AV, Naik AV, Pingale SG, Mangaonkar KV. Simultaneous determination of rofecoxib and tizanidine by HPTLC. E J Chem 2009; 6:295-302. https://doi.org/10.1155/2009/674742
25. Gandhimathi M, Ravi TK, Varghese SJ. Simultaneous LC determination of tizanidine and rofecoxib in tablets. J Pharm Biomed Anal 2005; 37:183-185. https://doi.org/10.1016/j.jpba.2004.09.039
26. Qi ML, Wang P, Wang L. Validated liquid chromatography method for assay of tizanidine in drug substance and formulated products. Anal Chim Acta 2003; 478:171-178. https://doi.org/10.1016/S0003-2670(02)01525-8
27. Raman B, Patil D. Reversed phase HPLC for simultaneous estimation of tizanidine and nimesulide in tablets. Indian Drugs 2002; 39:392-394.
28. Bhoir IC, Raman B, Sundaresan M, Bhagwat AM. Development of an isocratic SFC method for four centrally active muscle relaxant drugs. Anal Lett 1998; 31:1533-1542. https://doi.org/10.1080/00032719808002887
29. Drug Information Branch (HFD-210), Validation of analytical procedure: Meth-odology. Step 4. In: ICH Harmonized Tripartite Guidelines Q2B. Center for Drug Evaluation and Research, Rockville MD, 6 Nov, 1996.
30. Bakshi M, Singh B, Singh A, Singh S. The ICH guidance in practice: stress degradation studies on ornidazole and development of a validated stability-indicating assay. J Pharma Biomed Anal 2001; 26(5-6):891-7. https://doi.org/10.1016/S0731-7085(01)00475-7